tencent cloud

Stream Compute Service

JobManager CPU Load Too High

下载
聚焦模式
字号
最后更新时间: 2023-11-07 15:38:00

Overview

The JobManager of a Flink job manages and schedules the whole job. If its CPU load is too high, various exceptions may occur in the job. This event is triggered when the JobManager of the job is almost fully loaded for a long period of time.
Note
This feature is in beta testing, so custom rules are not supported. This capability will be available in the future.

Trigger conditions

The system detects the CPU utilization of the JobManager of a Flink job every 5 minutes.
If the CPU utilization of the JobManager exceeds 80% in 5 consecutive data points, its CPU load is considered to be too high.
Note
To avoid frequent alarms, at most one push of this event can be triggered per hour for each running instance ID of each job.

Alarm configuration

You can configure an alarm policy as instructed in Configuring Event Alarms (Events) for this event to receive trigger and clearing notifications in real time.

Suggestions

The reasons for a too-high JobManager CPU load are complicated. We recommend you configure more resources for the job as instructed in Configuring Job Resources, setting a larger JobManager spec, for example.
You can also submit a ticket to contact the technicians for help.

帮助和支持

本页内容是否解决了您的问题?

填写满意度调查问卷,共创更好文档体验。

文档反馈